Control grips, industrial joysticks, micro joysticks and electronic driver boards are the major products of Sure Grip Controls, a heavy duty equipment supplier in Kamloops of Canada.
#4-1413 McGill Road Kamloops, B.C., Canada V2C 6K7
Ph: (250) 374-2278 Fax: (250) 374-1099 Toll Free: 1-800-831-2278

www Sure Grip Controls
HOME COMPANY NEWS PRODUCTS INSTALLATIONS APPLICATIONS TECH.TIPS DOWNLOADS DEALERS CONTACTS
Home
Company
News
All Products
Control Grips
"K" Knob
"S" Series Handle
"C" Series Handle
"J" Series Handle
"L" Series Handle
Industrial Joysticks
"JM" Series Joystick
"JM" Specifications
"JM" Joystick 3D View
"JM" Joystick Parts List
"JM" Joystick Downloads
"JL" Series Joystick
Proportional Controls
Micro Joystick
Slider Module
Electronics
Inline Diode Pack
DFA Board
DBL-17 Logic Board
SDB-P1 Driver Board
Accessories
Switch Options
Variable Voltage Module
Proportional Buttons
Bushing Adapters
Studs
Rocker Kits
10 Button Keypad
Installations
Applications
Technical Tips
Downloads
Dealers
Contacts
"JM" JOYSTICK SPECIFICATIONS

JM Joystick Features
+ Non-contact, programmable Hall sensors
+ Adjustable gimbal mounting system
+ Long life - lab tested to 20 million cycles
+ Rugged design - die-cast metal housing
+ Infinite resolution + Single and dual axis models
+ Switched and Proportional outputs
+ Simple construction: only 3 moving parts
+ EMI/RFI protected
+ Stable null
+ Factory calibrated output range
+ Low power consumption

Proportional Voltage Output: (typical)
Supply voltage: 5.0 VDC (+/- 0.1 VDC) Supply current: 15 mA maximum Typical Output: 0.5 - 2.5 - 4.5VDC, (+/- 0.1 VDC)

Performance Specifications: (actual)
+ Output at maximum negative X or Y displacement: 8% +/- 4% of supply voltage
+ Actual Output at null (handle center): 50% +/- 2% of supply voltage
+ Output at maximum positive X or Y displacement: 92% +/- 4% of supply voltage
+ Maximum output current: 2mA (Outputs protected against shorts to supply or ground as long as supply voltage is within operational range, maximum survival voltage 18 VDC)

Switched Output Joystick
Momentary Switched:
24 VDC: 5 amps, (3 amps inductive)
120 VAC: 5 amps (3 amps @ 250 VAC)
Movement to Activate:
16 degrees, on axis (+/- 2 degrees)
22 degrees, at 45 degrees (+/- 2 degrees)

Common power wire to switches, spade connectors on wire harness. (If switching inductive loads, diode protection should be included in the circuit to maximum switch life)

Mechanical:
Maximum handle travel:
20 +/- 1 degrees (on axis)
28 +/- 1 degrees (at 45 degrees)
Force measured at bottom of faceplate (typical) to come out of center:
600 grams (on axis)
750 grams (at 45 degrees)
Force measured at bottom of faceplate (typical) at end of stroke:
750 grams (on axis)
900 grams (at 45 degrees)
Environmental Rating:
Joystick c/w J Series Basic Grip: IP-66
Joystick c/w any handle with trigger: IP-55

The pivot ball and centering shoe are molded using a high performance polymer-teflon blend that eliminates the need for additional lubricant. The joystick is designed to operate without the use of lubricating oil or grease.

Sure Grip On-Line
  • On-Line PDF Catalog

  • Related Links
  • JM Joystick Brochure.pdf
  • JM-Joystick Technical Info.pdf
  • JM Joystick Parts List.pdf
  • JM/JL EMI Report.pdf
  • JM Joystick 3D Step File
  • AutoCAD JM Joystick Drawing.zip

  • Download Center
  • General Info Downloads
  • Handle Info Downloads
  • Joystick Info Downloads
  • Electronics Info Downloads
  • Accessories Info Downloads

  • News Center
  • Current News
  • Sure Grip Development
  • Sure Grip History
  • Photo Gallery
  • All contents © 2007 SureGrip Inc. All rights reserved. ---Site Maps --- Designed by ID Tabs