TECHNICAL DATA (for 25 bar - version)
Working Pressure (pAmin): 20 bar
Pump pressure (pPmax): 50 bar
Tank pressure (Ptmax): 50 bar max. Static
Flow A->T (QA): 4 l/min at DP = 25 bar
Flow P->A (QA): 4 l/min at DP = 15 bar
Leakage volume flow: < 0.1 l/min. (for I = 0)
Control volume flow: < 0.5 l/min. (for I = max)
Hysteresis:
(based on pulse width modulated
control at 100 cycles per second) < 3 % from 22.5 bar
Dynamics 100 ms from 0 to 90 %
(as step response 100 % = 32 bar pA): 100 ms from 100 to 10 %
Ambient temperature: -30°C to +80°C
Medium temperature: -20°C to +80°C
Purity of hydraulic fluid: 17/14 under ISO 4406
Insulation class: 180°C (H under VDE 0580)
Permissible hydraulic fluids: Hydraulic fluids HL and
HLP under DIN 51524
Installed position: Any
Resistance R20 5 Ohm (12 V) 21,2 Ohm (24 V)
Limit Current IG 1,5 A (12 V)
0,75 A (24 V)
Duty cycle: 100 %
Weight: 0,23 kg

|